Effect of lubricant on the wear of prosthetic joint materials

No Thumbnail Available
Journal Title
Journal ISSN
Volume Title
Doctoral thesis (article-based)
Checking the digitized thesis and permission for publishing
Instructions for the author
Date
2001-11-28
Major/Subject
Mcode
Degree programme
Language
en
Pages
26, [45]
Series
Acta polytechnica Scandinavica. Me, 153
Abstract
The wear of ultra-high molecular weight polyethylene (UHMWPE) in prosthetic hip and knee joints is a significant clinical problem. The wear particles cause inflammatory tissue reactions which may lead to osteolysis and loosening of the implant fixation. The effect of lubricant on the wear of polyethylene was studied with a reciprocating pin-on-flat (RPF) apparatus, uniaxial (HUT-2) and three-axis (HUT-3) hip joint simulators, circularly translating pin-on-disk (CTPOD) device, biaxial rocking motion (BRM-1 and BRM-2) hip wear simulators, and a three-axis ball-on-flat (BOF) knee wear simulator. The aim was to produce wear similar to that known to occur clinically. To accomplish this, the basic criteria for the lubricant were: 1) no polyethylene transfer layer should form on the metal counterface, 2) the bearing surface of the polyethylene should become burnished, 3) the wear particle size should be of the order of 1 μm, and 4) the wear factor should be of the order of 1 x 10-6 mm3/Nm. The lubricants studied were human prosthetic joint fluid, bovine and calf serum, bovine albumin and gamma-globulin, soybean lecithin, dipalmitoylphosphatidylcholine (DPPC), soy protein, and distilled water. The counterfaces of polyethylene were CoCr, stainless steel, alumina, and diamondlike carbon (DLC). All the criteria were met by bovine and calf serum, albumin and gamma-globulin. Hence, albumin and gamma-globulin proved to be the crucial fractions of serum and synovial fluid with respect to producing clinically relevant wear of polyethylene. In conclusion, realistic wear was produced when the direction of sliding constantly changed relative to the polyethylene specimen, and a protein-based lubricant was used.
Description
Keywords
prosthetic joint, hip joint, knee joint, lubricant, polyethylene, wear
Other note
Parts
  • Saikko, V., Ahlroos, T., Phospholipids as boundary lubricants in wear tests of prosthetic joint materials. Wear Vol. 207 (1997), p. 86-91.
  • Ahlroos, T., Saikko, V., Wear of prosthetic joint materials in various lubricants. Wear Vol. 211 (1997), p. 113-119.
  • Saikko, V., Ahlroos, T., Type of motion and lubricant in wear simulation of polyethylene acetabular cup. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine Vol. 213 (1999), p. 301-310.
  • Saikko, V., Ahlroos, T., Wear simulation of UHMWPE for total hip replacement with a multidirectional motion pin-on-disk device: Effects of counterface material, contact area, and lubricant. Journal of Biomedical Materials Research Vol. 49 (2000), p. 147-154.
  • Saikko, V., Ahlroos, T., Calonius, O., Keränen, J., Wear simulation of total hip prostheses with polyethylene against CoCr, alumina and diamond-like carbon. Biomaterials Vol. 22 (2001), p. 1507-1514.
  • Saikko, V., Ahlroos, T., Calonius, O., A three-axis knee wear simulator with ball-on-flat contact. Wear Vol. 249 (2001), p. 310-315.
Citation
Permanent link to this item