Characteristics of segmented super clover detector in close geometry decay measurements
Rahkila, P., Grahn, T., Eskola, K., Gerl, J., Greenlees, P., Jones, P., Joss, D. T., Julin, R., Juutinen, S., Kankaanpää, H., Keenan, A., Kettunen, H., Kojouharov, I., Kuusiniemi, P., Leino, M., Melarangi, A., Moore, C. J., Muikku, M., Nieminen, P., . . . Uusitalo, J. (2001). Characteristics of segmented super clover detector in close geometry decay measurements. Acta Physica Polonica B, 32(3), 773. http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=773
Julkaistu sarjassa
Acta Physica Polonica BTekijät
Gerl, J. |
Päivämäärä
2001Tekijänoikeudet
© Authors, 2001
Characteristics of the segmented Super Clover germanium detector response in close geometries have been studied. Results obtained with localising hit pattern recognition are compared with results from add-back and individual crystal analysis. The detector has been used at the focal plane of a gas filled recoil separator to detect isomeric gamma-rays from the nuclei produced in the 150Sm(42Ca,4n)188Pb reaction. Coincidence data from the detector was analysed and the level scheme below the 1.2 μ s isomeric state in 188Pb could be deduced.
Julkaisija
Jagellonian UniversityISSN Hae Julkaisufoorumista
0587-4254Asiasanat
Alkuperäislähde
http://www.actaphys.uj.edu.pl/fulltext?series=Reg&vol=32&page=773Julkaisu tutkimustietojärjestelmässä
https://converis.jyu.fi/converis/portal/detail/Publication/26474045
Metadata
Näytä kaikki kuvailutiedotKokoelmat
Lisenssi
Samankaltainen aineisto
Näytetään aineistoja, joilla on samankaltainen nimeke tai asiasanat.
-
Characteristic measurements of a hybrid pixel detector
Ihanainen, Vesa (2021)Tässä tutkielmassa otan käyttöön ja karakterisoin fysiikan laitokselle hankitun ener- giasensitiivisen röntgenkameran Advacam WidePix L 1x10. Hankinnan tarkoituksena on mahdollistaa energiasensitiivinen kuvantaminen. Kameran ... -
Measurements of Low-Energy Protons using a Silicon Detector for Application to SEE Testing
Cazzaniga, Carlo; Alia, Ruben Garcia; Coronetti, Andrea; Bilko, Kacper; Morilla, Yolanda; Martin-Holgado, Pedro; Kastriotou, Maria; Frost, Christopher D. (IEEE, 2022)A silicon detector with a fast electronics chain is used for the dosimetry of protons in the range 0.5-5 MeV at the CNA 3 MV Tandem laboratory in Seville, Spain. In this configuration, measurements can be performed in ... -
Mass Measurements of Proton-rich Nuclei with JYFLTRAP
Eronen, Tommi (Jagiellonian University, 2011)The Penning trap setup JYFLTRAP, connected to the IGISOL facility, has been extensively used for atomic mass measurements of exotic nuclei. On the proton rich side of the chart of nuclei mass measurements have mostly ... -
Mass measurements of As, Se, and Br nuclei, and their implication on the proton-neutron interaction strength toward the N=Z line
Mardor, I.; Ayet San Andrés, S.; Dickel, T.; Amanbayev, D.; Beck, S.; Bergmann, J.; Geissel, H.; Gröf, L.; Haettner, E.; Hornung, C.; Kalantar-Nayestanaki, N.; Kripko-Koncz, G.; Miskun, I.; Mollaebrahimi, A.; Plaß, W. R.; Scheidenberger, C.; Weick, H.; Bagchi, Soumya; Balabanski, D. L.; Bezbakh, A. A.; Brencic, Z.; Charviakova, O.; Chudoba, V.; Constantin, Paul; Dehghan, M.; Fomichev, A. S.; Grigorenko, L. V.; Hall, O.; Harakeh, M. N.; Hucka, J.-P.; Kankainen, A.; Kiselev, O.; Knöbel, R.; Kostyleva, D. A.; Krupko, S. A.; Kurkova, N.; Kuzminchuk, N.; Mukha, I.; Muzalevskii, I. A.; Nichita, D.; Nociforo, C.; Patyk, Z.; Pfützner, M.; Pietri, S.; Purushothaman, S.; Reiter, M. P.; Roesch, H.; Schirru, F.; Sharov, P. G.; Spătaru, A.; Stanic, G.; State, A.; Tanaka, Y. K.; Vencelj, M.; Yavor, M. I.; Zhao, J. (American Physical Society (APS), 2021)Mass measurements of the nuclides 69As, 70,71Se, and 71Br, produced via fragmentation of a 124Xe primary beam at the Fragment Separator (FRS) at GSI, have been performed with the multiple-reflection time-of-flight mass ... -
The detection efficiency of the clover Ge-detectors array at the RITU-GREAT facility
Girka, Anastasiia (2015)Absolute detection efficiency depending upon its position along the beam line is determined for three germanium detectors, that are part of the GREAT spectrometer at the RITU separator focal plane. The efficiency is ...
Ellei toisin mainittu, julkisesti saatavilla olevia JYX-metatietoja (poislukien tiivistelmät) saa vapaasti uudelleenkäyttää CC0-lisenssillä.